CBQWR - NEOLUBE 1 DRY FILM CONDUCTIVE LUBE

  • MSDS: CBQWR
  • Manufacturer: HURON INDUSTRIES INC
  • Product Name: NEOLUBE 1 DRY FILM CONDUCTIVE LUBE
  • National Stock Number: 9150-01-304-6633
Product Identification

Product ID:NEOLUBE 1 DRY FILM CONDUCTIVE LUBE
MSDS Date:08/17/1992
FSC:9150
NIIN:01-304-6633
MSDS Number: CBQWR

Responsible Party
HURON INDUSTRIES INC
PORT HURON, MI 48060-0104
US

Emergency Phone: 313-984-4213

Info Phone: 313-387-3944

Preparer: DEBRA SULLIVAN

Cage: 03432

Contractor
HURON INDUSTRIES INC
610104 PORT HURON, MI 48061-0104 US

Telephone: 810-984-4213

Cage: 03432

Ingredients

ISOPROPYL ALCOHOL; (ISOPROPANOL) (SARA 313)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 94%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM; 500 STEL


GRAPHITE

CAS: 7782-42-5

RTECS: MD9659600

Fraction By Weight: 3-6%

OSHA PEL 15 MPPCF

ACGIH TLV: 2 MG/M3 RDUST


766 G/L (METHOD - EPA 24)

RTECS: 9999999VO


FIRE BURN. WITHDRAW IMMEDIATELY IN CASE OF RISING


OF TANK DUE TO FIRE.


OF IGNITION & FLASH BACK. CNTNR MAY EXPLODE IN


OR IN SEWERS. RUNOFF TO SEWER MAY CREATE FIRE OR


PLACE INTO CONTAINERS FOR LATER DISPOSAL. LARGE

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: VAPORS OR MISTS CAN CAUSE
NASAL AND RESPIRATORY IRRITATION, DIZZINESS, NAUSEA, HEADACHE.
INGESTION: CAN CAUSE GASTROINTESTINAL IRRITATION, VOMITING AND
DIARRHEA. EYES: CAN CAUSE SEVERE IRR ITATION, BURNING SENSATION,
BLURRED VISION. SKIN: REPEATED OR PROLONGED CONTACT CAN CAUSE
IRRITATION AND DERMATITIS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. CALL MD . INHAL:
IF AFFECTED, REMOVE INDIVIDUAL TO FRESH AIR. IF BREATHING IS
DIFFICULT, ADMINISTER OXYGEN. IF BREATHING HAS STOPPED, GIVE
ARTIFICIAL R ESPIRATION AND SEEK MEDICAL ATTENTION IMMEDIATELY.
INGEST: KEEP INDIVIDUAL CALM AND SEEK MEDICAL ATTENTION. EYES:
FLUSH WITH WATER FOR AT LEAST 15 MINUTES.

Fire Fighting

Flash Point Method:TCC
Flash Point:52.0F,11.1C
Lower Limits:2.0%
Upper Limits:12.0%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:KEEP AWAY FROM SPARKS, OPEN FLAMES OR
OTHER SOURCES OF IGNITION.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION AND VENTILATE
AREA. APPLY ABSORBENT MATERIAL AND TRANSFER TO CONTAINERS.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF MISTS OR VAPORS.

Exposure Controls

Respiratory Protection:IF TLV IS EXCEEDED NIOSH/MSHA APPROVED
MECHANICAL OR SELF-CONTAINED BREATHING APPARATUS IS ADVISED.
Ventilation:PROVIDE SUFFICIENT LOCAL EXHAUST VENTILATION TO MAINTAIN
EXPOSURE LEVELS BELOW TLV(S).
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Spec Gravity:0.79 (H*2O=1)
Solubility in Water:SLIGHT
Appearance and Odor:GREY FLUID; SHARP ODOR.
Percent Volatiles by Volume:98

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:CONSULT WITH FEDERAL, STATE AND LOCAL
REGULATIONS.

======================================================================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their